RVS1000 Series Rugged Sinewave Inverter

Benefits
- Ultra-Quiet
- Power sensitive electronics without interference
- Rugged & Reliable
- Ensure years of safe and trouble free operation
- Download Data Sheet
The RVS1000 Series compact, low-profile DC/AC inverter utilizes established design techniques to deliver 1000VA sine wave voltage. Suitable for a wide range of applications, the RVS1000 features full electronic protection, high efficiency and low output noise.
Internal modules are encapsulated within a thermally conductive MIL-spec silicon rubber compound to ensure resistance against shock, vibration, moisture, humidity, salt, fog, dust, and insects. The unit is conduction cooled. Extended operating temperature ranges are available.
The RVS1000 is housed in a 19”x14”x 3” chassis-mount enclosure. The demonstrated MTBF of the unit exceeds 250,000 hours.
Features
- Input is filtered to EN 55022 Class A (minimum)
- Low Profile, Compact Size
- Sinusoidal wave shape
- 1000VA of output power
- Full electronic protection
- Field-proven design topology
Applications
- Marine / Automotive / RV
- Electric Utilities and Substations
- Telecom Power Plants
- Manufacturing Locations
- Steel Mills
- Military Applications (COTS)
- Industrial Controls
- OEM Applications
- Solar / Alternative Power Systems
- Fuel Cells
| Input Voltage | 24V, 36V, 48V, 125V, 250VDC +20% / -15% are standard Consult factory for other inputs |
|---|---|
| Input Protection | Thermal fuse / Inrush current limiting / Reverse polarity protection |
| Isolation | Input to chassis: 1500VDC / Input to output: 3000VDC/ Output to chassis: 2250VDC |
| Output Voltage | 115VAC @ 8.7A or 230V @ 4.34A continuous at 50, 60 or 400Hz with grounded neutral Isolated floating output optional (Consult factory for other output requirements) |
| Wave Form | Sinusoidal |
| Total Harmonic Distortion | Less than 5% at full load |
| Efficiency | Min. 78% at full load |
| Line Regulation | Better than 0.5% |
| Load Regulation | Better than ± 2% from no load to full load |
| Output Protection | Current limiting with short circuit protection, thermal shutdown with automatic recovery in case of continuous overload or insufficient airflow |
| EMI | EN 55022 Class A as a minimum |
| Load Crest Factor | Maximum 3.0 at 90% load |
| Operating Temperature Range | 0 °C to +50°C (Wider temperature range available) |
| Humidity | 5 - 95% non-condensing |
| Temperature Drift | 0.05% per °C over operating temperature range |
| Packaging | Fully encapsulated and potted internal modules |
| Dimensions | 19” x 14” x 2.7” enclosed case |
| Connections | Input/output: compression-type terminal block (Phoenix SMKDS 5/3-9,6) |
| Weight | 15 lb (7 kg) |
| Safety | Designed to meet C22.2 No. 107.1 - 01, UL 458 , EN60950 and EN50155 |
| Options | Output Fail Alarm (Form C) Remote Inhibit: By closing external contacts on the inhibit terminals |
| Warranty: Twenty Four months subject to application within good engineering practice Enhancements to these general specifications can be accommodated upon request Designed to meet common approval requirements. Specifications Subject to Change Without Notice Designed and Manufactured in Canada |
|
Toll Free: 1-800-668-3884
Tel: 604.946.9981
Fax: 604.946.9983
Email Us
Facebook/Twitter/LinkedIn: