BCD1000R-300-12

Features

  • Fully Isolated Design
  • Adjustable output voltage for charging standard or deep cycle lead-acid, VRLA or Gel cell type battery
  • Transient Voltage Suppressor
  • Extremely rugged and well suited for marine and other demanding environments
  • High tolerance for shock and vibration
  • Ultra-quiet low EMI operation
  • Can be left permanently connected
  • Spark free connection
  • User selectable 2 or 3 stage charging profile
  • Audible & visual indicators for output overload, low input voltage, low output voltage & over-temperature
  • Over-temperature shutdown
  • Short circuit protection
  • Output over-voltage crowbar
  • Inrush Current Limiting with solid state bypass
  • Dry contact output fail relay
  • Three year warranty (parts & labor)

Three Year Warranty Seal

The model BCD1000R Rackmount DC Battery Charger charges either 12V, 24V or 48V batteries from a 110, 220 or 300VDC power source. Other battery voltages up to 72 volts are also available by special order.

The all-new Current Mode switching design offers increased power and reliability in a compact package. Extra input and output filtering reduce EMI to extremely low levels. Reliability features include an input fuse, thermal shutdown, current limiting, reverse battery hookup protection, output short circuit shutdown with automatic recovery and an equalize charge mode. The output voltage is easily adjusted 1.0 volts above or below the standard output voltage to accommodate special charging requirements.

A high quality Digital Volt/Ammeter allows the monitoring of charging current and charging voltage. We are confident that you will get many years of reliable service from this DC Battery Charger.

SKU: BCD1000R-300-12 Categories: , ,

Description

60A, 12V Out, 280-360V In, Isolated DC/DC Battery Charger, 2 Bank

Additional information

Specialization

Rackmount Configuration

Function

Battery Charger

Conversion

DC to DC

Power (Watts)

1000

Input Volts

280 – 360 VDC

Output Volts

12 VDC

Output Amps Continuous

60

Input/Output Isolation

Yes

Technology

Analog

Charging Stages

3

Temperature Compensation

Yes

Equalize

Yes

Battery Banks

2

Product Series on website

BCA1000R

Option Codes

OPT-C: MIL461F & MIL810G Tested, OPT-E: Not assigned, OPT-I: MIL461 Tested Only, OPT-J: MIL810 Tested Only, OPT-M: Military Rugged, OPT-O: Open Frame – No chassis, OPT-Q: 23 Inch Rackmount, OPT-R: 19 Inch Rackmount, OPT-U: Safety Special Inspection (CSA/SPE-1000), OPT-V: Digital Volt/Ammeter, OPT-X: Ruggedized & Wide Temp, OPT-Z: No Conformal Coating (Any Model)

Downloads

Download BCD1000R Series Datasheet
Download BCD1000R Series Manual

If the above links are not connected, the file is being updated, please contact sales for more information.